More advance technology More comfortable therapy
Five Components of Intelligent Therapy
System One humidity control and Dry Box technology
Better humidification management to prevent rainout and water damage.
Even in changing environmental conditions, consistent humidification levels are preserved throughout each night thanks to our advanced humidity control technology. By analyzing ambient temperature, relative humidity and patient flow, the device delivers optimum humidity – and ultimate comfort – to the patient while also dramatically reducing rainout. Our new Dry Box technology assures the humidifer’s water source is isolated from the inner workings of the device during any normal and most uncommon conditions.
System One resistance control
Optimized pressure delivery, no matter which mask is used.
System One Resistance Control achieves complete system comfort by enabling the device and mask to work optimally together. Through simple settings, the technology instructs the device to compensate for variable resistance characteristics related to different masks. The result is synchronous pressure delivery and the assurance patients can enjoy the full benefits of our Flex comfort technologies no matter which mask is used.
Advanced event detection
Identification of complicated and changing conditions that may indicate alternative therapy.
We’ve built in more device intelligence so that you can make the most informed decisions possible. Our new sleep system addresses advanced sleep assessment parameters, including AHI, leak, flow limitation and RERAs to provide optimum therapy for obstructive sleep apnea (OSA). With our new system, events can now be verified by looking at detailed patient flow waveform data captured by the device. But the real advancement is its ability to point out when the patient is experiencing symptoms beyond classic OSA. With intelligent technology that can identify conditions such as clear airway apneas and periodic breathing, the system immediately indicates the potential need for specialized therapy. That means the care team will have the ability early on to identify different treatment that may be needed.
Flex Family technologies
Improved patient comfort with proven pressure relief.
Our natural and clinically-proven technologies that enhance traditional pressure therapy – C-Flex, Bi-Flex, A-Flex, and now C-Flex+ in our fixed-CPAP mode advanced units – are an excellent way to establish improved patient comfort, and increased compliance. Thanks to our advanced Digital Auto-Trak algorithm that detects the onset of inspiration and exhalation, our flex technologies deliver just the right pressure relief for every breath, making it easier for patients to adapt to therapy. Each Philips Respironics Sleep Therapy System device with a Flex option also has an on-board Flex Demo mode to allow patients to feel the difference for themselves. It’s as easy as pressing a button.
Encore data management and reporting
Intelligent patient management for improved compliance.
The best intelligence is only valuable if it’s easily accessible. That’s why we’ve made sure vital patient information is available through multiple options of data transfer and reporting including memory cards and modems.* Our new devices now include on-board data memory. Putting more patient intelligence in your hands is a key component of effective patient therapy and compliance management.
*Not available in all countries.
Fully Automatic
Automatically adjusts the variable trigger and cycle thresholds to maintain optimum performance.
Advance functions of Bi-Flex
- By tracking each breath, Bi-Flex delivers pressure relief at three critical points in the breathing cycle: the transition from exhalations to inhalation, the transition from inhalation to exhalation and during exhalation. This helps to make each breath more comfortable and natural.
- Digital Auto-Trak algorithm imitates human breathing pattern enabling the sleep device to facilitate the air movement in and out of the lungs. User will feel more comfortable.
- Ramp function allows users to have a reduced pressure initially and then increases gradually until the prescribed pressure is reached. This provides more time for user to adapt & fall into sleep.
- With 3 selectable comfort settings, users can adjust the degree of pressure relief to make therapy more closely match their needs.
- Leak compensation is available to maintain optimum performance in the presence of any leaks and ensure optimum response with every breath.
- With leakage alarm
Automatic Pressure Adjustment
Adjust exhalation and inhalation pressure delivery breath-by-breath, to maximize patient comfort and therapy result.
Product Specifications
Pressure: IPAP, EPAP, 4 to 25 cm H2O
Ramp Time: 0 to 45 minutes (5-min. increments) and automatic on/off system
Starting Ramp Time: 4 to EPAP; patient adjustable
Data Storage Content:
Encore Pro SD: Date/time, hours of usage, usage patterns, AHI, leak, snore, FOSQ
Dimensions:
3 lbs, 18 (L) x 14 (W) x 10 (H) cm
Others:
Operating Sound level: less than 28db
Voltage: Universal voltage, 100 – 240 VAC, 50/60 Hz
Optional humidifier is available.
(Coming soon)
|