Product Name : BiPAP Pro 2 with Bi-Flex
Model No. : EQ00494

 

Building long-term compliance is always a challenge, and

 

 
That’s why we’re so excited to introduce the BiPAP Pro 2 with Bi-Flex – a reliable, proven approach to treatment that makes breathing more natural, especially at expiration. With a pressure range to 25 cm H2O, Bi-Flex allows you to comfortably treat patients with severe OSA. BiPAP Pro 2 also features integrated humidification and build-in Encore® Pro SmartCard® recording capability for added flexibility in treatment and follow-up.
 
We feel that this all adds up to the ideal tool for treating non-compliant CPAP users. But don’t take our word for it, because with the BiPAP Pro 2, breathing is believing.
 
Bi-Flex. Breathing is Believing.
 
For typical OSA patients using CPAP therapy, we offer our revolutionary C-Flex™ technology. C-Flex offers a more comfortable CPAP experience by talking the work out of exhalation. But Bi-Flex takes our “Flex” technology to new levels, offering the ultimate in therapy comfort, especially for hard-to-treat patients.
 
Bi-Flex “softens” the airflow in inhalation and exhalation, making breathing more natural – and unbelievably more comfortable – for the patient. In the Bi-Flex mode, the amount of pressure relief at the end of inhalation and at the beginning of exhalation is established. Patient-adjustable settings of “1”, “2” or “3” provide progressively increased pressure relief.
 
Digital Auto-Trak™ Sensitivity.
 
Digital Auto-Trak Sensitivity and Bi-Flex work together to deliver more natural – and unbelievably comfortable – therapy. Digital Auto-Trak Sensitivity triggers the BiPAP Pro 2 to cycle between inspiratory and expiratory pressure based on the patient’s breathing rhythm. It also automatically adjusts the variable trigger and cycle thresholds to maintain optimum performance in the presence of any leaks and ensures optimum system response with every breath.
 
Integrated humidification. Added treatment flexibility.
 
BiPAP Pro 2 uses the same integrated approach to heated humidification as Respironics’ proven REMstar® family of CPAPs. That makes it easy for you to stock and for patients to use. The lighted controls are part of the BiPAP Pro 2 unit, so they’re always easy to find. And since the heater platform plugs into the device, there’s only one plug to go into the wall.
 
Encore Pro Compatible. Enhanced recording capability.
 
The BiPAP Pro 2 with Bi-Flex comes complete with Respironics’ Encore Pro SmartCard technology. Now BiPAP Pro 2 and the SmartCard record events such as snores, apneas and hypopneas. That gives you even more insight into your patietns’ therapy – so you can make therapy better for patients and better for you.
 
The SmartCard also records the data, time, ramp usage and duration of each BiPAP Pro 2 use. When combined with the Encore Pro software, the usage data can be downloaded and viewed. The SmartCard can also transfer the prescribed pressure settings to the device.
 
The BiPAP Pro 2 with Bi-Flex also features the Functional Outcomes of Sleep Questionnaire (FOSQ). Patients can periodically complete the questionnaire and record quality-of-life data on the SmartCard. This data, along with Encore Pro’s enhanced reporting capabilities and longer-term monitoring of patients, can be used as part of an overall compliance assessment.
 
Specification

Modes of operation:
Bi-level, Bi-level with Bi-Flex
Pressure range:
IPAP: 4 cm H2O to 25 cm H2O
EPAP: 4 cm H2O to 25 cm H2O
Starting ramp pressure:
4 cm H2O to EPAP level
Ramp time:
0 to 45 minutes. (5-minute increments)
Ramp activation:
Unlimited number of ramps per night
Dimensions:
9.45” (l) x 6.69” (w) x 4.72” (h)
24 cm (l) x 17 cm (w) x 12 cm (h)
Weight:
< 4 lbs. (1.8 kg)
Filters:
Reusable Pollen and optional Ultra-fine
Device set-up:
On-board keypad and SmartCard
Data storage capacity
6 months @ 3 usage sessions/day;
7 days in-depth data analysis
Data storage content:
Date, time, duration at pressure, patient event histograms, short-term detailed events, long-term treads, POSQ tests
Compliance meter:
Breathing detection;
Session > 4 hours
Altitude compensation:
Automatic
Electrical requirements:
100 – 240 VAC
24 VDC (when operated with the external DC power adaptor accessory)
DC power:
Direct-connect cord
Warranty:
2 years
MISC:
Integrated heated humidification, lighted keys on pad, automatic on/off, mask off alert

 